File Format
6-24
The LX-120 attaches the following information after DEVICE.
When the tachometer pulse input channel is set
PULSE_CH_A Tachometer pulse input channel number, 9 for the LX has 8 analog inputs.
PULSE_MODE_A Tachometer pulse input mode, number of bits, measurement mode number, range
setting
Measurement Mode 0: Pulse counter mode, gate
1: Pulse counter mode, total
2: Cycle count mode
3: Frequency mode
4: RPM mode
PULSE_LEVEL_A Threshold level
DIVIDE_RATE_A Divided rate
MOVE_AVERAGE_A Moving average
PULSE_PER_1R_A Number of pulse per revolution
The LX may not generate some of above information depending on the selected measurement mode.