Ratoc Systems CBFW3 Manuel d'instructions Page 95

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 146
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 94
Convenient Features
5-17
Channel Property
Converting Units
You can use engineering units, instead of the physical units to be written in the VERT_UNITS line of the
header file. The coefficient (SLOPE value) is converted accordingly and written in the header file.
In the above dialog box, the entered conversion expression is for the situation in which you are recording a
signal from an acceleration sensor outputting an acceleration of 9.8 m/s2 by 1 V. If the offset value exits for
input of 0V, enter the Offset Value. When these are changed, the units for VERT_UNITS and the SLOPE
and Y_OFFSET values in the header file will change.
Value of cursor
position
Differences between 2 c
ursors
position value
Double click the desired channel
Coefficient value and units
Unit conversion expression
Offset value
Return to the
default
Return to the
default
Change the display
range
Channel name
Graph
background
color
Graph line color
Reset the graph color settings to the
default
Vue de la page 94
1 2 ... 90 91 92 93 94 95 96 97 98 99 100 ... 145 146

Commentaires sur ces manuels

Pas de commentaire